Monoblock Container

Containers

Monoblock Container

Product overview

Fast, flexible and controlled spaces with Monoblock Container.

Monoblock containers are practical structures manufactured around a one-piece main chassis and upper frame, offering fast dispatch and rapid commissioning. They can be configured as offices, sales points, storage units, field rooms or temporary living spaces. Insulated panels, a robust steel frame and flexible door and window positions allow the building to respond to different climates and operating scenarios. Electrical and, when required, plumbing infrastructure can be completed during production to reduce site work and shorten the handover programme.

3 model options

Choose the area and compare the detail.

These are concept options. Final dimensions and technical solutions are confirmed against site, regulations and engineering.

18 m² Monoblock Container Model
18

18 m² Monoblock Container Model

18 m² Monoblock Container Model is configured for compact requirements with an approximate external footprint of 6 × 3 m. The schematic plan contains Multipurpose Area, Technical Niche. Door and window positions, service points and partitions can be revised around site conditions and user capacity before manufacture.

Get a Quote

Technical specifications

Model18 m² Monoblock Container Model
Gross floor areaApproximately 18 m²
External dimensions6 × 3 m
Building height2.60 m
Clear internal heightApproximately 2.30–2.55 m, depending on roof and service design
Structural systemS235 grade steel main chassis and box-section upper frame, sized by structural calculation
Internal wall50 mm painted panel or plasterboard-lined light steel partition; moisture-resistant finish in wet areas
External wall50–80 mm insulated sandwich panel with painted galvanised steel faces; core selected for the climate
RoofGalvanised structure, vapour-control layer, 80–100 mm insulation and waterproof outer covering
FloorCement-based board over galvanised floor frame with heavy-duty commercial PVC finish
External door90 × 210 cm insulated galvanised steel entrance door; glazed or double-leaf options by model
Internal doorsLaminate, PVC or moisture-resistant compact doors selected for the use area
WindowsDouble-glazed PVC or thermally broken aluminium frames; opening sash and insect-screen options
ElectricalHalogen-free cabling, LED lighting, power/data points and provision for RCD-protected distribution board
PlumbingFresh/wastewater and hot-water provision in models with wet areas; optional in other layouts
Thermal and acoustic insulationSpecified by project according to climate zone, occupancy period, fire strategy and acoustic target
Plan scheduleMultipurpose Area, Technical Niche

Note: Technical values are a concept framework. The final building is engineered for the site, climate, seismic, fire and local requirements.

Additional model options

36 m² Monoblock Container Model
36 m²

36 m² Monoblock Container Model

36 m² Monoblock Container Model is configured for mid-scale requirements with an approximate external footprint of 12 × 3 m. The schematic plan contains Open Work Area, Meeting Room, Storage. Door and window positions, service points and partitions can be revised around site conditions and user capacity before manufacture.

Get a Quote

Technical specifications

Model36 m² Monoblock Container Model
Gross floor areaApproximately 36 m²
External dimensions12 × 3 m
Building height2.60 m
Clear internal heightApproximately 2.30–2.55 m, depending on roof and service design
Structural systemS235 grade steel main chassis and box-section upper frame, sized by structural calculation
Internal wall50 mm painted panel or plasterboard-lined light steel partition; moisture-resistant finish in wet areas
External wall50–80 mm insulated sandwich panel with painted galvanised steel faces; core selected for the climate
RoofGalvanised structure, vapour-control layer, 80–100 mm insulation and waterproof outer covering
FloorCement-based board over galvanised floor frame with heavy-duty commercial PVC finish
External door90 × 210 cm insulated galvanised steel entrance door; glazed or double-leaf options by model
Internal doorsLaminate, PVC or moisture-resistant compact doors selected for the use area
WindowsDouble-glazed PVC or thermally broken aluminium frames; opening sash and insect-screen options
ElectricalHalogen-free cabling, LED lighting, power/data points and provision for RCD-protected distribution board
PlumbingFresh/wastewater and hot-water provision in models with wet areas; optional in other layouts
Thermal and acoustic insulationSpecified by project according to climate zone, occupancy period, fire strategy and acoustic target
Plan scheduleOpen Work Area, Meeting Room, Storage
54 m² Monoblock Container Model
54 m²

54 m² Monoblock Container Model

54 m² Monoblock Container Model is configured for large-scale requirements with an approximate external footprint of 12 × 4.5 m. The schematic plan contains Reception, Work Area, Meeting Room, Archive, WC. Door and window positions, service points and partitions can be revised around site conditions and user capacity before manufacture.

Get a Quote

Technical specifications

Model54 m² Monoblock Container Model
Gross floor areaApproximately 54 m²
External dimensions12 × 4.5 m
Building height2.60 m
Clear internal heightApproximately 2.30–2.55 m, depending on roof and service design
Structural systemS235 grade steel main chassis and box-section upper frame, sized by structural calculation
Internal wall50 mm painted panel or plasterboard-lined light steel partition; moisture-resistant finish in wet areas
External wall50–80 mm insulated sandwich panel with painted galvanised steel faces; core selected for the climate
RoofGalvanised structure, vapour-control layer, 80–100 mm insulation and waterproof outer covering
FloorCement-based board over galvanised floor frame with heavy-duty commercial PVC finish
External door90 × 210 cm insulated galvanised steel entrance door; glazed or double-leaf options by model
Internal doorsLaminate, PVC or moisture-resistant compact doors selected for the use area
WindowsDouble-glazed PVC or thermally broken aluminium frames; opening sash and insect-screen options
ElectricalHalogen-free cabling, LED lighting, power/data points and provision for RCD-protected distribution board
PlumbingFresh/wastewater and hot-water provision in models with wet areas; optional in other layouts
Thermal and acoustic insulationSpecified by project according to climate zone, occupancy period, fire strategy and acoustic target
Plan scheduleReception, Work Area, Meeting Room, Archive, WC
You imagine it. We make it real.

Let’s plan your project

You imagine it. We make it real.

Tell us the need, location and target handover date. Together, we will define the right model, scope and delivery route.

Get a Quote