Panel Cabin

Cabins

Panel Cabin

Product overview

Fast, flexible and controlled spaces with Panel Cabin.

Panel cabins offer an economical and rapid solution for security, field office, reception, sales or technical-room requirements. A light steel frame and insulated panel envelope create a durable and easily transportable building in a compact footprint. Doors, windows, electrical points, counters and cooling provisions are positioned during production for the intended role. Easy-care surfaces and a clean façade make the system suitable for industrial facilities, commercial sites and public spaces.

3 model options

Choose the area and compare the detail.

These are concept options. Final dimensions and technical solutions are confirmed against site, regulations and engineering.

6 m² Panel Cabin Model
6

6 m² Panel Cabin Model

6 m² Panel Cabin Model is configured for compact requirements with an approximate external footprint of 3 × 2 m. The schematic plan contains Multipurpose Area. Door and window positions, service points and partitions can be revised around site conditions and user capacity before manufacture.

Get a Quote

Technical specifications

Model6 m² Panel Cabin Model
Gross floor areaApproximately 6 m²
External dimensions3 × 2 m
Building height2.50 m
Clear internal heightApproximately 2.30–2.55 m, depending on roof and service design
Structural systemGalvanizli hafif çelik taban. dikme ve çatı karkası; proje yüklerine göre boyutlandırma
Internal wall50 mm painted panel or plasterboard-lined light steel partition; moisture-resistant finish in wet areas
External wall50–80 mm insulated sandwich panel with painted galvanised steel faces; core selected for the climate
RoofGalvanised structure, vapour-control layer, 80–100 mm insulation and waterproof outer covering
FloorCement-based board over galvanised floor frame with heavy-duty commercial PVC finish
External door90 × 210 cm insulated galvanised steel entrance door; glazed or double-leaf options by model
Internal doorsLaminate, PVC or moisture-resistant compact doors selected for the use area
WindowsDouble-glazed PVC or thermally broken aluminium frames; opening sash and insect-screen options
ElectricalHalogen-free cabling, LED lighting, power/data points and provision for RCD-protected distribution board
PlumbingFresh/wastewater and hot-water provision in models with wet areas; optional in other layouts
Thermal and acoustic insulationSpecified by project according to climate zone, occupancy period, fire strategy and acoustic target
Plan scheduleMultipurpose Area

Note: Technical values are a concept framework. The final building is engineered for the site, climate, seismic, fire and local requirements.

Additional model options

12 m² Panel Cabin Model
12 m²

12 m² Panel Cabin Model

12 m² Panel Cabin Model is configured for mid-scale requirements with an approximate external footprint of 4 × 3 m. The schematic plan contains Work Area, Depo Nişi. Door and window positions, service points and partitions can be revised around site conditions and user capacity before manufacture.

Get a Quote

Technical specifications

Model12 m² Panel Cabin Model
Gross floor areaApproximately 12 m²
External dimensions4 × 3 m
Building height2.50 m
Clear internal heightApproximately 2.30–2.55 m, depending on roof and service design
Structural systemGalvanizli hafif çelik taban. dikme ve çatı karkası; proje yüklerine göre boyutlandırma
Internal wall50 mm painted panel or plasterboard-lined light steel partition; moisture-resistant finish in wet areas
External wall50–80 mm insulated sandwich panel with painted galvanised steel faces; core selected for the climate
RoofGalvanised structure, vapour-control layer, 80–100 mm insulation and waterproof outer covering
FloorCement-based board over galvanised floor frame with heavy-duty commercial PVC finish
External door90 × 210 cm insulated galvanised steel entrance door; glazed or double-leaf options by model
Internal doorsLaminate, PVC or moisture-resistant compact doors selected for the use area
WindowsDouble-glazed PVC or thermally broken aluminium frames; opening sash and insect-screen options
ElectricalHalogen-free cabling, LED lighting, power/data points and provision for RCD-protected distribution board
PlumbingFresh/wastewater and hot-water provision in models with wet areas; optional in other layouts
Thermal and acoustic insulationSpecified by project according to climate zone, occupancy period, fire strategy and acoustic target
Plan scheduleWork Area, Depo Nişi
18 m² Panel Cabin Model
18 m²

18 m² Panel Cabin Model

18 m² Panel Cabin Model is configured for large-scale requirements with an approximate external footprint of 6 × 3 m. The schematic plan contains Work Area, Kitchenette, WC. Door and window positions, service points and partitions can be revised around site conditions and user capacity before manufacture.

Get a Quote

Technical specifications

Model18 m² Panel Cabin Model
Gross floor areaApproximately 18 m²
External dimensions6 × 3 m
Building height2.50 m
Clear internal heightApproximately 2.30–2.55 m, depending on roof and service design
Structural systemGalvanizli hafif çelik taban. dikme ve çatı karkası; proje yüklerine göre boyutlandırma
Internal wall50 mm painted panel or plasterboard-lined light steel partition; moisture-resistant finish in wet areas
External wall50–80 mm insulated sandwich panel with painted galvanised steel faces; core selected for the climate
RoofGalvanised structure, vapour-control layer, 80–100 mm insulation and waterproof outer covering
FloorCement-based board over galvanised floor frame with heavy-duty commercial PVC finish
External door90 × 210 cm insulated galvanised steel entrance door; glazed or double-leaf options by model
Internal doorsLaminate, PVC or moisture-resistant compact doors selected for the use area
WindowsDouble-glazed PVC or thermally broken aluminium frames; opening sash and insect-screen options
ElectricalHalogen-free cabling, LED lighting, power/data points and provision for RCD-protected distribution board
PlumbingFresh/wastewater and hot-water provision in models with wet areas; optional in other layouts
Thermal and acoustic insulationSpecified by project according to climate zone, occupancy period, fire strategy and acoustic target
Plan scheduleWork Area, Kitchenette, WC
You imagine it. We make it real.

Let’s plan your project

You imagine it. We make it real.

Tell us the need, location and target handover date. Together, we will define the right model, scope and delivery route.

Get a Quote